The following first focuses on the three basic product classifications of LED lamps, LED bulbs and LED drivers, and the UL safety standards and special precautions that should be referred to when using them in various finished products or parts, as a basic guide for industry players who want to conduct product safety testing. However, this table is only for readers' reference, and the actual classification of the product still needs to be determined based on the product's purpose and its use environment.
Application Products | Safety Standards | Precautions |
LED lamps | ||
Indicator Lights | UL 48 | - |
Handle lamps, kitchen cabinet lamps, table lamps, floor lamps, wall lamps, etc. (all with power cords) | UL 153 | Covers portable lighting fixtures that are connected to a branch circuit rated at 120 volts and 15 or 20 amperes by means of a power cord. |
Christmas Light String | UL 588 | - |
Emergency lights, exit lights | UL 924 | - |
Display cabinets, mirror lights | UL 962 | - |
Stage lights | UL 1573 | - |
Step lamps, ceiling lamps, chandeliers, wall lamps, street lamps, column lamps, etc. (all without power cords) | UL 1598 | Covers fixed luminaires used in non-hazardous areas and installed on branch circuits less than 600 V. |
Night Light | UL 1786 | - |
Low voltage garden light (without power cord plug) | UL 1838 | - |
Water pipe light | UL 2388 | - |
LED Bulbs | ||
Indicator light bulb | UL 496 | - |
LED bulb (ANSI Base), including driver circuit | UL 1993 | E27 Base is a European standard and cannot be used in the North American market. The North American market requires E26 Base |
LED bulb (non-ANSI Base), with driver circuit inside | UL 496 | - |
LED module, without driver circuit | UL 60950-1 | - |
LED Drivers | ||
Power supply (with LPS safety circuit) | UL 60950-1 | Output LPS safety circuit, then LED module and LED control module do not need electrical enclosure |
Power supply (without Class 2 safety circuit) | UL 1012 | LED modules and LED control modules must be provided with appropriate electrical enclosure protection |
Power supply (with Class 2 safety circuit) | UL 1310 | Output Class 2 safety circuit, LED module and LED control module do not require electrical enclosure |
Driver (with LPS/Class 2 safety circuit) | UL 935 | Output LPS / Class 2 safety circuit, LED module and LED control module do not need electrical enclosure |
Low Voltage Garden Light Power Supply | UL 1838 | LED modules and LED control modules must be provided with appropriate electrical enclosure protection |